Communication protocols

The set of supported communication protocols is still being extended. Each of the protocol documentations describes the current state. You can find here information on configuration of communication lines, stations and I/O tags for individual protocols. Only some of the supported communication protocols are described in the on-line help. Documentation of the others is available on demand.

Communication protocol Operating system Line category Redundancy support Target column of structure
ABB SRIO X3.28 all Serial, SerialOverUDP Device Redundant Yes  
ABB Elektro Win32 FILE I/O    
ABB SPA-Bus all Serial, SerialOverUDP Device Redundant Yes  
Advantech ADAM 4000 Series all Serial, SerialOverUDP Device Redundant Yes  
Advantech ADAM 5000 DeviceNet Win32 API    
Advantech Data Acquisition Card Win32 API    
Allen-Bradley CSP/PCC (Client Server Protocol / Programmable Controller Communication Command) all TCP/IP-TCP Yes  
Allen-Bradley DF1 Full Duplex all Serial, SerialOverUDP Device Redundant Yes  
Allen-Bradley DH485 Win 32 KMFB02 Allen-Bradley DH485    
Alfa Laval Combimass all Serial    
ALYA Gina all Serial, SerialOverUDP Device Redundant    
ALYA Lubrikacie all Serial, SerialOverUDP Device Redundant Yes  
ALYA MMP Win32 API    
ALYA SPOOL Win32 Serial, SerialOverUDP Device Redundant    
ALYA VT200 all TCP/IP-UDP Yes  
AMiT ATOUCH32 DB-Net Win32 API   Yes
AMiT ARION all Serial, SerialOverUDP Device Redundant    
ASCII Client/Server all Serial Yes  
BACnet Win32 TCP/IP-UDP, LonWorks    
Contal CR all Serial, SerialOverUDP Device Redundant    
Datalogger ESC8800 all Serial    
Datalogger ESC8816 all Serial, SerialOverUDP Device Redundant, TCP/IP-TCP Yes  
DDE Client Win32 DDE client    
Diamo-L KOS/SOS all Serial, SerialOverUDP Device Redundant    
DLMS/COSEM all Serial, SerialOverUDP Device Redundant, MODEM    
EDW LPEX V2.0 all FILE I/O Yes  
Elcor ELGAS Daniel all Serial, SerialOverUDP Device Redundant Yes  
Elcor ELGAS-2 (CP II) all Serial, SerialOverUDP Device Redundant Yes  
Fisher-Rosemount RS3 RNI Win32 API    
Fisher-Rosemount RS3 SCI all Serial, SerialOverUDP Device Redundant    
Generic User all Serial, Serial Line Redundant, Serial System&Line Redundant, MOXA IP Serial Library, TCP/IP-TCP, TCP/IP-TCP Redundant, SerialOverUDP Device Redundant, SerialOverUDP Line Redundant, SerialOverUDP System&Line Redundant, Yes  
HART all Serial, SerialOverUDP Device Redundant, TCP/IP-TCP, TCP/IP-TCP Redundant Yes  
Hivus Win32 Serial, MOXA IP Serial Library    
Honeywell Excel C-Bus Win32 KMFB02 Honeywell C-Bus    
Honeywell PCNM Win32 API    
HOPF 7515 all Serial, SerialOverUDP Device Redundant    
Hydrolab DATASONDE 4a all Serial    
ID-Innovations RFID ASCII all Serial, SerialOverUDP Device Redundant Yes  
ID-Karta IdxAPI Win32 API    
IEC62056-21:2002 File I/O Win32 FILE I/O Yes  
IEC62056-21:2002 Serial all Serial, SerialOverUDP Device Redundant, MODEM Yes  
IEC 870-5-101 (balanced, unbalanced primary, unbalanced secondary) all Serial,
Serial Line Redundant,
MOXA IP Serial Library,
SerialOverUDP Device Redundant,
SerialOverUDP Line Redundant,
SerialOverUDP System&Line Redundant
Yes  
IEC 870-5-104 all TCP/IP-TCP, TCP/IP-TCP Redundant Yes  
IEC 870-5-104 Server all TCP/IP-TCP Yes  
IEC 870-5-104 Sinaut all TCP/IP-TCP Redundant Yes  
IEC 60870-6 ICCP/TASE.2 all TCP/IP-TCP, TCP/IP-TCP Redundant Yes  
IND690 all Serial, SerialOverUDP Device Redundant    
Incos/VUVT PMEL 04 all Serial, SerialOverUDP Device Redundant Yes  
Johnson Controls N2-Bus all Serial, SerialOverUDP Device Redundant    
KMZ Lite Protocol
KMZ Protocol
all TCP/IP-TCP Yes  
LFC (IEC 870-5) all Serial, TCP/IP-UDP, SerialOverUDP Device Redundant Yes  
LonTalk Win32 LONWORKS    
L&G ProfiBus Win32 KMFB02 L&G ProfiBus    
L&G PRV Fugga all Serial, SerialOverUDP Device Redundant    
L&G Toccata all Serial, SerialOverUDP Device Redundant Yes  
L&G Toccata via UNIP2 all Serial, SerialOverUDP Device Redundant Yes  
LoRaWAN SerialOverUDP Device Redundant, TCP/IP-TCP API Serial  
MDIS device Windows API    
MEN-SMB2 device Windows API    
MESIT Devices all ASYNC, SerialOverUDP Device Redundant    
Microtel 700 all Serial, SerialOverUDP Device Redundant, TCP/IP-UDP Yes  
MODBUS Client all Serial, SerialOverUDP Device Redundant, TCP/IP-TCP, TCP/IP-TCP Redundant Yes  
MODBUS Server all Serial, SerialOverUDP Device Redundant, TCP/IP-TCP Yes  
MODBUS Circutor CVMk all Serial    
MODBUS Codel DSU all Serial, SerialOverUDP Device Redundant    
MODBUS RTU Quad2000 all Serial    
MODBUS Telemecanique TSX all Serial, SerialOverUDP Device Redundant    
MODBUS Valmet Damatic RTU all Serial    
MODBUS SCT PPU all Serial, SerialOverUDP Device Redundant Yes  
M-Bus Rev. 4.8 all Serial, SerialOverUDP Device Redundant, MOXA IP Serial Library    
MT Printer all Serial, SerialOverUDP Device Redundant    
MQTT Client (Message Queue Telemetry Transport) all TCP/IP-TCP Yes  
NMEA-0183 all Serial, SerialOverUDP Device Redundant, File I/O Yes  
OMV24 all Serial, SerialOverUDP Device Redundant Yes  
OneSoft devices all Serial, SerialOverUDP Device Redundant Yes  
OPC Data Access 2.05 & Client Win32 OPC Client Yes Yes
OPC Historical Data Access 1.20 Client Win32 OPC Client    
OPC Unified Architecture Data Access Client all OPC UA Client No Yes
OPC XML Data Access 1.01 Client all OPC XML Yes  
Orange GDEP all TCP/IP-TCP    
Paufex DIRAS all Serial    
Paufex DIRAS-B all Serial    
PCMBA/IEC870-FT1.2 all Serial, SerialOverUDP Device Redundant    
PCMBA/IEC870-FT1.2 Scan all Serial, SerialOverUDP Device Redundant    
Plantscape ODBC Win32 API    
Premex CALMEX II all Serial, SerialOverUDP Device Redundant Yes  
Remia E3 all Serial, SerialOverUDP Device Redundant, TCP/IP-UDP    
Remia KME all TCP/IP-UDP Yes  
RFE Win32 FILE I/O    
SAE RTU all Serial, SerialOverUDP Device Redundant, TCP/IP-TCP Yes  
Servomex XENTRA 4900 all Serial    
SHMU Data all MODEM    
Siemens SAPHIR all TCP/IP-TCP, TCP/IP-TCP Redundant    
Siemens SIMATIC 3964(R) all Serial    
Siemens SIMATIC RK512 all Serial, SerialOverUDP Device Redundant    
Siemens SIMATIC S7 ISO on TCP all TCP/IP-TCP, TCP/IP-TCP Redundant Yes Yes
SMS gateway all MODEM    
SNMP all TCP/IP-UDP Yes  
Telegyr 809 Server all Serial,
Serial Line Redundant,
Serial System&Line Redundant,
SerialOverUDP Device Redundant,
SerialOverUDP Line Redundant,
SerialOverUDP System&Line Redundant,
TCP/IP-TCP
Yes  
Teltonika Codec14 all TCP/IP-TCP    
Transcon DAP 128TC all Serial, SerialOverUDP Device Redundant Yes  
UNIP all Serial, SerialOverUDP Device Redundant Yes  
Wonderware Industrial SQL Win32 API    
Wonderware InBatch API Win32 API    
ZPA INMAT 64/65 all Serial, SerialOverUDP Device Redundant    
ZPA INMAT 51/66 Win32, OpenVMS, Linux Serial, SerialOverUDP Device Redundant Yes  