Parameter | Description | Unit | Default value |
| The address of the master station (D2000 KOM process) is a number in the range 0 to 255. | - | 0 |
| The number of request retries in case of a communication failure. | - | 3 |
| First waiting for a response after sending the request. | ms | 100 ms. |
| The delay between individual readings of the response until its completing. | ms | 100 ms. |
| Retry count of response reading until its completing. | - | 50 |
| Activate a permanent passive mode (Scan only) without sending requests and only processing received messages. | YES/NO | NO |
| Full communication monitoring. It enables to show the I/O tag values and other debug information. | YES/NO | NO |
| The start address of the block of DI data (digital inputs). Blok's length is 500 words, data are 16-bit binary numbers. The parameter is used only for communication logs and analysis. | - | 0 |
| The start address of the block of DO data (digital outputs). Blok's length is 250 words, data are 16-bit binary numbers. The parameter is used only for communication logs and analysis. | - | 500 |
| The start address of the block of EV data. Blok's length is 250 words, data are 16-bit binary numbers with timestamps. The parameter is used only for communication logs and analysis. | - | 750 |
| The start address of the block of AI data (analog inputs). Blok's length is 500 words, data are 32-bit binary numbers. The parameter is used only for communication logs and analysis. | - | 1000 |
| The start address of the block of AO data (analog outputs). Blok's length is 500 words, data are 32-bit binary numbers. The parameter is used only for communication logs and analysis. | - | 1500 |
| The start address of Time Write data where time is written during time synchronization. Data's length is 9 words, data is BCD encoded. | - | 2300 |
| The start address of Event data. The data is 4 words in length, the data are 32-bit binary numbers (containing 10-bit SPACOM Unit Number, 7-bit Channel Number and 5-bit Event Number which can be specified in the I/O tag configuration) with a time stamp. | - | 2400 |
| The size of the block of data specified in the BLOCK_READ data request sent by the KOM process (2-244 bytes). | bytes | 100 |
| A period (10-1440 minutes) in which the D2000 KOMprocess performs readout of all data (integrity readout). | min | 15 |
Diagnostic Request Timeout | A period (10-60 sekúndseconds) in which the D2000 KOMprocess sends a diagnostic request (DIAG_LOOP) to verify line functionality. | s | 5 |
String A string containing the protocol parameters is defined as follows:
...
If a keyword with a valid value is not found in the initialization string, there a corresponding default value will be used (see the table above).
...
- Word Address: 16-bit data address in device memory (0-65535) used during readout of all data (see Read Data Timeout).
- SPACOM Unit (Di tags only): optional 10-bit address of SPA Unit (0-1023) within the SPACOM system.
- Channel (Di tags only): optional 7-bitová adresa bit address of SPA Channel (0-127) within the SPACOM system.
- EventNr 0->1 (Di tags only): optional 6-bit number of Event (0-63), that will cause transition to True value True.
- EventNr 1->0 (Di tags only): optional 6-bit number of Event (0-63), that will cause transition to False value False.
Note: Optional address items SPACOM Unit, Channel, EventNr 0->1, EventNr 1->0 are used when the Di I/O tag§s tag's value is to be set after the arrival of Event Data.
Changes and modifications
...