Expression of String type - its value will
be written into log database (the column
Incident). Maximum characters: 200 (a text is cropped from the right).
LINENO
in
Optional key word. If it is entered, the script line
which the action is placed in is to be written to the log database
(the
column
Incident).
prtyExpr_Int
in
Expression of Int type
that determines a priority of storing the log into the log database. Its
value must be within the range of _LOG_PRTY_INFO
(0) .. _LOG_PRTY_ERROR(5). If it is not, the action generates the
error _ERR_RANGE_ERROR.
Description
The action will perform a log into the log database. Text is
characterized by value of expression strExpression (in contrast to LOG action).
Example
BEGIN
REAL _temperature
_temperature := 1.123
LOGEX "Temperature=" + %IToStr (_temperature) PRIORITY _LOG_PRTY_CRITALARM
END