%PerfCounter, %PerfCounterR functions
Function
The function returns the value of the given "Performance Counter".
Declaration
Blok kódu | ||||
---|---|---|---|---|
| ||||
INT %PerfCounter( TEXT in text ) |
Blok kódu | ||||
---|---|---|---|---|
| ||||
REAL %PerfCounterR( TEXT in text ) |
Parameters
text | Performance Counter definition. |
Description
Performance Counter definition syntax is as follows:
\\ComputerName\Object(instance)\Counter.
If you want to monitor the counter on local computer, the first part giving the computer name may omitted. If an object has only one instance, the part "instance" is omitted.
If the function %PerfCounter (%PerfCounterR) is called frequently (more times than once per second), it returns wrong values (0).
If there is the need to call function each second for more system information, we recommend you to execute each calling on the different line in ESL script.
Example
Blok kódu | ||||
---|---|---|---|---|
| ||||
%PerfCounter("\D2000 Server\MemUsed") ; returns the memory size used by process D2000 Server |
Note 1
In some situation (for specific counters) %PerfCounter returns always zero at first calling, e.g. for load counter of processor: " \Processor(_Total)\% User Time". Then you must call this function twice in a loop with delay (the size must be set empirically) between the callings.
For other counters (e.g. "\Memory\Available MBytes", "\LogicalDisk(C:)\% Free Space" or "\Process(_Total)\Handle count"), this function works without any problems and returns the correct value immediately at first call.
Apparently, there is some a problem with the counters that require requires a certain time between the registration of counter and loading its value.
For other counters (e.g. "\Memory\Available MBytes", "\LogicalDisk(C:)\% Free Space" or "\Process(_Total)\Handle count"), this function works without any problems and returns the correct value immediately at first call.
Apparently, there is some a problem with the counters that require requires a certain time between the registration of counter and loading its value.
This is an example of the code which calls %PerfCounter twice with the delay of 0.1 second if the value 0 has been loaded at first calling:
Blok kódu | ||||
---|---|---|---|---|
| ||||
INT _i REAL _result FOR _i=1 TO 2 DO_LOOP _result := %PerfCounter("\Processor(_Total)\% User Time") IF _result\VLD THEN IF _result=0 & _i=1 THEN ; workaround - at first calling (e.g. it returns 0 on \Processor (_Total)\% User Time) DELAY 0.1 [s] ELSE EXIT_LOOP ENDIF ELSE EXIT_LOOP ENDIF END_LOOP |
This code does not work because the same row is not called twice, the same instance of PerfCounter function:
Blok kódu | ||||
---|---|---|---|---|
| ||||
INT _i REAL _result _result := %PerfCounter(_counter) IF _result\VLD THEN IF _result=0 THEN ; NONFUNCTIONAL workaround - at first calling (e.g. it returns 0 on \Processor(_Total)\% User Time) DELAY 0.05 [s] _result := %PerfCounter(_counter) ENDIF ENDIF |
Note 2
We recommend to use %PerfCounterR when it is assumed that the value will be higher than 2 147 483 647.