Incos PMEL 04 communication protocol

Supported device types and versions
Communication line configuration
Communication station configuration
I/O tag configuration
Literature
Changes and modifications
Document revisions

Supported device types and versions


The communication with the impulse power meters Incos/VUVT PM_EL 04 involves obtaining:

  • accumulated work for 3 tariffs
  • instantaneous power
  • quarter-hour power take-off, including the archival data

Communication line configuration


Communication station configuration


  • Communication protocol: Incos/VUVT PMEL 04.
  • A station address is a decimal number - according to the settings of PMEL configuration jumpers.
  • A time synchronization of station is required.

Station protocol parameters

Communication station - configuration dialog box - tab "Protocol parameters".
They could influence some optional protocol parameters. You can set the following parameters:

Table 1

Key word Full name Meaning Unit Default value
RC Retry Count Number of call retries when an error in communication occurs. - 2
RT Retry Timeout Delay between the retry call when an error in communication occurs. ms 1000
WFT Wait First Timeout The first timeout for response reading after sending the message. ms 500
WT Wait Timeout Timeout between the response readings until it is completed. ms 500
MWR Max Wait Retry Number of retries of response reading until it is completed. - 8
SADDR Source Address Communication address of source (PC). 0 up to 254 126
PMEL04B PMEL04B Communication with PMEL04B device. YES/NO NO
TIMEST Timestamp There is used PMEL04B with the support of time stamp transmission. YES/NO NO
TMSYNC Allow Automatic Time Synchro Real time will be synchronized after the bit EM_TIM is set by a device (only PMEL04B). YES/NO YES

I/O tag configuration


  • I/O tags: Ai, Di, TiA, TiR.
  • I/O tag address is a decimal number in the range 0 up to 255.

Table 2: I/O tag addresses distribution:

Electro meter Instantaneous power (Ai) Accumulation work tariff 1 (Ai) Accumulation work tariff 2 (Ai) Accumulation work tariff 3 (Ai) Quarter-hour power take-off (Ai) Time difference between curr. and prev.  state (TiR)
1 0 16 17 18 64 200
2 1 19 20 21 65 201
3 2 22 23 24 66 202
4 3 25 26 27 67 203
5 4 28 29 30 68 204
6 5 31 32 33 69 205
7 6 34 35 36 70 206
8 7 37 38 39 71 207
9 8 40 41 42 72 208
10 9 43 44 45 73 209
11 10 46 47 48 74 210
12 11 49 50 51 75 211
13 12 52 53 54 76 212
14 13 55 56 57 77 213
15 14 58 59 60 78 214
16 15 61 62 63 79 215

Table 3: Di values, status bits (only PMEL04A):

Address Meaning
0 EPROM error.
1 RAM error.
5 Program restart on a process module.
6 Exceeding the time difference.
7 Acknowledgement of time settings.

Di values, digital inputs (only PMEL04B), addresses 0 up to 15.


Table 4: Di values, status bits (only PMEL04B):

Address Meaning
100 RES_CNT
107 EM_TIM
108 EM_ROM
109 EM_RAM
110 TDIFOVR

Literature


-

Changes and modifications


-

Document revisions


  • Ver. 1.0 - February 18, 2000 - Creation of document
  • Ver. 1.1 - March 13, 2008 - Updating