The system is informed by the function %CloseRefToObject
that the script has not already interest in Object Values.
Declaration
%CloseRefToObject(
HBJ in _hbj
)
Parameters
_hbj
Value of the HBJ type or INT type.
Description
The system is informed that the script has not interest in
Object Value (regardless of the number of the previous callings of the
%OpenRefToObject function).
If the function is not called by the script
before his termination the function will be called automatically after
script termination.