Supported device types and versions
Literature
Document revisions
This protocol is implemented in D2000 via ESL script using the Generic User Protocol. The implementation communicated with Pentimex PREMOVA 60-2-8 and Pentimex PREMOVA 60-3-8 platform scales with a capacity of 60 tons used for weighting cargo vehicles. These scales were connected to a DINI Argeo DFW06 control panel, which communicated via a serial port with an application Cestná váha by VTnet company on a PC.
The implementation of the protocol supports separate polling of the control panel as well as eavesdropping on existing communication.
Literature
You can read blogs about DINI Argeo DFW06 protocol: Communication - DINI ARGEO DFW06 control panel. |