Supported device types and versions
Communication line configuration
Communication station configuration
I/O tag configuration
Literature
Changes and modifications
Document revisions


Supported device types and versions



The ICOM Voice Recorder protocol is intended for recording digital audio communication of ICOM repeaters (in AMBE2+ format). From the ICOM side, recording is supported for repeaters UC-FR5300 in multisite trunking mode, with firmware Revision 1.50 (NXDN)Beta.

In the configuration of the system master repeater in the settings in the "Recording" section, it is necessary to configure "Recording Server IP Address" to the address of the computer with the D2000 KOM process and "Recording Server Port" to the UDP port number where the D2000 KOM process will listen. Subsequently, all repeaters will start sending copies of UDP packets with sound to the specified address and port.


Communication line configuration



Category of communication line:


Communication station configuration



Station protocol parameters

The following station protocol parameters can be specified:


Full NameDescriptionUnitDefault value

Work Path

The working directory in which recordings are made. A symbolic constant #APPDIR# can be used to specify the application directory, e.g. #APPDIR#/my_work

-#APPDIR#/icom/work

Done Path

Directory to which closed recordings are moved. A symbolic constant #APPDIR# can be used to specify the application directory, e.g. #APPDIR#/my_done

-#APPDIR#/icom/done

Recording Timeout

Waiting for recording to close. If this timeout expires and no more recording data has been received during it, the recording file is closed and moved to the Done Path directory.

sec.mss3.000

Full Debug

Enabling detailed debugs about receiving and analyzing data.YES/NONO


I/O tag configuration



Possible value types of I/O tag: TxtI, Ci.


The I/O tags can be configured on the station according to the following table:


Value typeI/O tag address New valueDescription
TxtIIP_ADDRNew recordingThe IP address of the sending repeater
CiSRC_SYSCODENew recordingStores the System Code of the sender (1-16382)
CiSRC_SITECODENew recordingStores the transmitters' Site Code (1-250)
CiSRC_PREFIXIDNew recordingStores the Prefix ID of the transmitter (1-30)
CiSRC_UNIT_IDNew recordingStores the Unit ID of the transmitter (1-2000)
CiSRC_RPTR_NONew recordingStores the transmitter's Repeater No. (1-30)
CiDST_SYSCODENew recordingStores the System Code of the destination (1-16382)
CiDST_SITECODENew recordingStores the Site Code of the destination (1-250)
CiDST_PREFIXIDNew recordingStores the Prefix ID of the destination (1-30)
CiDST_UNIT_IDNew recordingStores the Unit/Group ID of the destination (1-2000,2047)
CiCALL_TYPENew recordingCall type (1-group call, 4-individual call)
TxtIFILE_READYEnd of recordingThe name of the closed file in the Done Path directory
TxtIERRORError occurrenceFatal error processing UDP packet, the packet is dropped
TxtIWARNINGWarning occurenceMinor error while processing UDP packet, processing continues


Literature



Changes and modifications



-


Document revisions




Communication protocols