Supported device types and versions
Communication line configuration
Station configuration
I/O tag configuration
Document revisions

Supported device types and versions



The protocol supports reading data from electrometers (active and reactive energies) that were collected by ABB Microscada system and published via files.
The files are expected to have a name in a format coding both the date and the time Dyyyymmddhhmi.CSV, e.g. D201706301247.CSV.
The files are read with the time parameters (period, delay) configured on the station's Time parameters tab.
The protocol only supports data readout.

Communication line configuration


File I/O communication line configuration parameters:

Station configuration


Station protocol parameters

Dialog window station configuration - tab "Protocol parameters".
They influence some optional protocol parameters. The following station protocol parameters can be entered:

ParameterDescriptionUnitDefault Value
Delay After Processing File
Delay after processing of a file. The parameter can be useful if the communication has been offline for a longer time, i.e. a larger number of files are accumulated and their fast processing could flood the system.s0

I/O tag configuration


Supported value types of I/O tags: Ai.

I/O tag address is an integer 16-bit number (1-65535) specified as a decimal number or as a hexadecimal number with a hash at the beginning (e.g. #0A).
It defines an electrometer number, which is specified on every line of a data file.
This is an example of the first 15 rows of a specific file (I/O tag addresses would be 1-15):

E001;0
E002;6504
E003;0
E004;0
E006;3620
E007;1160
E008;196
E009;884
E010;152
E011;400
E012;140
E013;3588
E014;0
E015;0

Document revisions