Value typeAddressDescription
I/O tag for handling barcode readers.
TxtI, Ci0Cone number from the message received from barcode readers (CONE_NR)
I/O tags for handling input from the scales.
Ai, Ci, Di, TxtI1 .. 10Individual components of the received message from the scales. According to the specification, there are five components (addresses 1-5):
  • ID - identifier of a message
  • CONE_NR - the cone number of cone
  • WEIGHT - the weight of the cone measured by the multi-measurement workstation (MMP)
  • WIDTH - the width of the cone (diameter of the reel)
  • HEIGHT - the height of the cone (width of the reel)
Should the message be extended, the D2000 supports defining up to 10 components without any modification of the protocol implementation.
Di0A trigger I/O tag for the message from the scales.
It is set to True with a new timestamp when a new message from the scales arrives and the input I/O tags from the previous row of the table have their values set by D2000 KOM.
I/O tags for handling the answer for the scales.
Co, TxtO, Ao1 .. 32Individual components of a response to the scales. According to the specification, there are seven components (addresses 1-7):
  • ID - identifier of a message (must be equal to the identifier of a message received from the scales).
  • MACHINE - the number of a site where a cone was reeled
  • PRODUCT - the name of a product
  • LENGTH - the length of a fibre reeled on a cone
  • QUALITY - the qualitative rating of the coil
  • DATE - date and time when reeling was completed
  • OPERATOR - the name of the operator of the site where a cone was produced
Should the message be extended, the D2000 supports defining up to 32 components without any modification of the protocol implementation.
Note: component with address 2 cannot by of TxtO type, to avoid the collision with a trigger for the fibre rupture message.
Dout0Trigger I/O tag for the response to the scales. By writing to the trigger the application activates sending the response that contains the output I/O tags from the previous row of the table.
The number of values in the reply is determined by the configuration parameter Nr. Of Values for Output.
I/O tags for sending spontaneous messages about the rupture of the fibre to the scales.
Co, TxtO, Ao1The first component of a spontaneous message about a rupture of the fibre sent to the scales.
Kotva
tr2
tr2
TxtO
2The second component and at the same time a trigger of a spontaneous message about a rupture of the fibre sent by D2000 KOM process to the scales.
The message contains components with addresses 1 and 2.

...