- Communication line category: TCP/IP TCP.
- Server host: all or * (TCP server), server port: well-known port according to the setting of the device.
...
Following station protocol parameters can be configured:
Table 1
Full name | Meaning | Unit | Default value |
---|
| A number of the connected units handled by one thread. It is used for balancing the power and the response of communication process in dependence on the number of connected units. | 1 up-to 200 | 50 |
Send Async Message Request After Connect | KOM process will send 'Asynchronous Message Request' after a unit is connected. The unit will answer by 'Asynchronous Message Response' which contains the data (AVL record). | YES/NO | YES |
| Activation of debug information about the received and sent datagrams. | YES/NO | YES |
| Activation of debugging information about received values. | YES/NO | NO |
| Activation of debugging information about the state of received data processing by D2000 System. | YES/NO | NO |
Debug Packet Binary Contents | Enabling of debug listings containing the received/sent datagrams in binary form. | YES/NO | YES |
| Enabling of a special form of tracing the units when the debug information is saved into a special file. The name of this file is derived from the IP address of the unit (IP1_IP2_IP3_IP4.log) in the "trace" subdirectory of the application directory. It makes easier the identification of debug lists from the unit.
Meaning of parameters:
Not_Allowed | - the file will not be created | Both Line & Station | - the file will be created in parallel with the standard .log file which traces the communication line | Station Only | - only special log files are allowed Warning! This setting overrides the level setting of communication tracing in the line configuration (see also the information in document Communication lines - configuration dialog box, section Communication tracing). |
| Not Allowed Both Line & Station Station Only | Not Allowed |
| Maximal size of the special debug file of unit tracing. After the file reaches this size, it will be renamed and saved like the file of communication line tracing. | 1 up-to 50 MBytes | 10 |
I/O tag configuration
...
List of I/O tag addresses
Table 2
Address | Meaning | Value type |
---|
HND.TRIG | Message handshaking - an issue of the new increment value signalizes the setting of all I/O tag values with the values of the received record and that they are ready to be processed. | Ci |
HND.TRIG_ACC | Message handshaking - acknowledges that data was processed by the application. It is executed by the writing of value HND.TRIG and signalizes that the KOM process can create the next record. | Co |
STAT.CONN_NR | Global Statistic - an actual number of the handled TCP connections. | Ci |
STAT.IN_QUEUE_LEN | Global Statistic - number of received data files that are not sent to the system yet. | Ci |
STAT.RD_TASKS_NR | Global Statistic - number of received threads. |
|
STAT.VIRT_ST_NR | Global Statistic - the actual number of connected units with a unique IMEI. |
|
UNIT_DATA.IMEI | Unit data - IMEI unit which data was received from. | TxtI |
UNIT_DATA.DTIME | Unit data - timestamp of received data. The timestamp of the value of all I/O tags UNIT_DATA.xxx is identical. | TiA |
UNIT_DATA.LAT | Unit data - latitude. | Ai |
UNIT_DATA.LON | Unit data - longitude. | Ai |
UNIT_DATA.ALT | Unit data - altitude (m). | Ai |
UNIT_DATA.PRIO | Unit data - data priority (0/1). | Ci |
UNIT_DATA.SAT | Unit data - number of the visible satellites. | Ci |
UNIT_DATA.SPEED | Unit data - speed (km/h). | Ci |
UNIT_EVENT.EvNr | Unit event - the value of the received events number EvNr. More detailed information on the events is mentioned in the literature about protocol Codec14. | Ai/Di/Ci/TxtI |
UNIT_DEBUG.DbgNr | Unit debug - debug information with index DbgNr. More detailed information on the events is mentioned in the literature about protocol Codec14. | Ai/Di/Ci/TxtI |
UNIT_STAT.ST_BYTES_IN | Unit statistic & info - number of the received bytes from the unit since the KOM process has been started. | Ci |
UNIT_STAT.ST_BYTES_OUT | Unit statistic & info - number of sent bytes to the unit since the KOM process has been started. | Ci |
UNIT_STAT.ST_CONFIG_TIMESTAMP | Unit statistic & info - so-called config timestamp of the unit. | TiA |
UNIT_STAT.ST_CONNECTED | Unit statistic & info - state of the connection (1-connected, 0-disconnected); only when the state is changed. | Ci |
UNIT_STAT.ST_CONNECTS | Unit statistic & info - total number of the unit connections since the KOM process has been started. | Ci |
UNIT_STAT.ST_FW_VER | Unit statistic & info - the version of the unit firmware. | TxtI |
UNIT_STAT.ST_PACKETS_IN | Unit statistic & info - number of the received datagrams from the unit since the KOM process has been started. | Ci |
UNIT_STAT.ST_PACKETS_OUT | Unit statistic & info - number of the sent datagrams to the unit since the KOM process has been started. | Ci |
UNIT_RESTART.IMEI | Unit restart request - when the IMEI value is written into this I/O tag, a request to restart the unit with this IMEI is sent. If the writing failed, the unit is not connected. | TxtO |
UNIT_MONITORING.IMEI | Unit monitoring request - when the IMEI value is written into this I/O tag, the request to monitor the unit with this IMEI is sent. If the writing failed, the unit is not connected. | TxtO |
UNIT_ASYNCMESS.IMEI | Async message request - when the IMEI value is written into this I/O tag, a request to receive the asynchronous info from the unit with this IMEI is sent. If the writing failed, the unit is not connected. | TxtO |
UNIT_DEBUG.IMEI | Unit debug request - when the IMEI value is written into this I/O tag, a request to receive the debug info from the unit with this IMEI is sent. The unit will respond by sending UNIT_DEBUG.DbgNr values. If the writing failed, the unit is not connected. | TxtO |
UNIT_FW_UPD.PARAMS | Firmware update request - when the requested information is written, the process of firmware update for the unit with given IMEI is initialized. The format of data: IMEI,APN,APNuser,APNpasswd,server:port,fw_filename. More detailed information on the events is mentioned in literature about protocol Codec14. | TxtO |
UNIT_PARAMS_OUT.IMEI | Unit parameters write messaging - IMEI of the unit which the changes of the configuration parameters are sent to. | TxtO |
UNIT_PARAMS_OUT.ADDR | Unit parameters write messaging - address of the written parameter (parameter ID). | Co |
UNIT_PARAMS_OUT.VALUE | Unit parameters write messaging - the value of the written parameter. | TxtO |
UNIT_PARAMS_OUT.VALUE_TYPE | Unit parameters write messaging - the value type of the written parameter. | Co |
Parameter writing
The following rules hold:
- The values of parameters can be only written, not read.
- The check, if the writing was all right, is made through the so-called Configuration Timestamp (I/O tag with address UNIT_STAT.ST_CONFIG_TIMESTAMP). The value "Config Timestamp" must be set during the parameters writing - it is the parameter with ID = 0 (Profile Timestamp). The value should be the unique absolute time (the best is the time of the configuration start).
After the parameters were written, the value UNIT_STAT.ST_CONFIG_TIMESTAMP must be set on the value of the parameter with ID=0 sent by the user. - Process of writing:
- Set IMEI to I/O tag UNIT_PARAMS_OUT.IMEI, if it ends with error (on an action WAIT) the KOM process does not recognize the unit with this IMEI or it is not online.
- Set the value type of parameter to UNIT_PARAMS_OUT.VALUE_TYPE (see the Table 3).
- Set UNIT_PARAMS_OUT.VALUE with the value of the parameter (as text).
- Set UNIT_PARAMS_OUT.ADDR with the parameter ID. The parameter ID=0 "Profile Timestamp" should be the first.
- Set UNIT_PARAMS_OUT.VALUE_TYPE of next parameter.
- Set UNIT_PARAMS_OUT.VALUE with the value of the next parameter.
- Set UNIT_PARAMS_OUT.ADDR with the parameter ID of next parameter.
.... repeat as many times as many parameters you are writing. You need not write all the parameters but only those changed..... - Set UNIT_PARAMS_OUT.VALUE_TYPE to value 1 to finish the configuration.
- Set UNIT_PARAMS_OUT.VALUE - empty text to finish the configuration.
- Set UNIT_PARAMS_OUT.ADDR to value 0. It is a signal to send parameters into the unit physically.
Table 3
Type of value "UNIT_PARAMS_OUT.VALUE_TYPE" | Parameter ID "UNIT_PARAMS_OUT.ADDR" | Meaning |
---|
1 | 0 | End of configuration. |
2 | x | Parameter of U8 type. |
3 | x | Parameter of I32 type. |
4 | x | Parameter of String type. It is allowed to use it for all the parameters except for the parameter with ID=0. The user is responsible for the text correctness, the KOM process does not check it. |
6 | x | Parameter of U16 type. |
8 | x | Parameter of Float type. |
10 | x | Parameter of U32 type. |
11 | 0 | Parameter "Profile Timestamp" - a text with absolute time in the form: "dd-mm-rrrr hh:mi:ss". |
Literature
...