Addresses of I/O tags for Capacitive level meter type LM1.2134:
Table 2
Address | I/O tag type | Description | ||||||
---|---|---|---|---|---|---|---|---|
3.79.1.1 | Ci | Basic data - level meter status. The documentation states the following possible values:
| ||||||
3.79.2.4 | Ai | Basic data - the volume of fuel in the tank. Linear conversion required A = 0.001, B = 0, the result is volume in liters. | ||||||
3.79.6.4 | Ai | Basic data - relative permittivity. Linear conversion required A = 0.001, B = 0, the result is relative permittivity. | ||||||
3.79.10.4 | Ai | Basic data - fuel temperature in °C. | ||||||
3.105.1.2 | TxtI | Identification - text part of the serial number (two characters). | ||||||
3.105.3.2 | Ci | Identification - numeric part of the serial number (2-byte value 0-65535). | ||||||
3.105.5.9 | TxtI | Identification - 9-character product number (tested sample had "LM1.21345"). | ||||||
3.105.14.8 | TxtI | Identification - 8-character firmware version (tested sample had "LM1-2.50"). | ||||||
4.68 4.68#228 | TxtO | Calibration - clear the current calibration curve by entering an empty value "". | ||||||
4.83 4.83#235.233 | TxtO | Calibration - write a new calibration curve. In the value of the I/O tag it is necessary to enter individual bytes in decimal form, which are separated by a "#" character. | ||||||
6 6#220 | TxtO |
| ||||||
7 7#231 | TxtO |
| ||||||
9.70.1.1 | Ci | Time filter - time filter period (in seconds). The setting is possible within setting the time filter parameters. | ||||||
9.70.2.1 | Di | Time filter - hardening of the time filter. A value of TRUE means that it is a working machine and that filter hardening is switched on. The setting is possible within setting the time filter parameters. | ||||||
9.75.1.2 | Ci | Theft condition - fuel loss measurement period (in seconds). The setting is possible within the setting of theft conditions. | ||||||
9.75.3.2 | Ci | Theft condition - the maximum allowable loss of fuel (in liters) for the period during which it is not yet theft. The setting is possible within the setting of theft conditions. | ||||||
9.75.5.2 | Ci | Theft condition - the time of the length of switching on the status output when theft is detected (in seconds). The setting is possible within the setting of theft conditions. | ||||||
12.78.1.2 | Ai | Accelerometer - the tilt of the X-axis. Linear conversion A=0.006, B=-180 is required, the result is an angle from the interval <-90°… 90°>. | ||||||
12.78.3.2 | Ai | Accelerometer - the tilt of the Y-axis. Linear conversion A=0.006, B=-180 is required, the result is an angle from the interval <-90°… 90°>. | ||||||
12.78.5.2 | Ai | Accelerometer - the tilt of the Z-axis. Linear conversion A=0.006, B=-180 is required, the result is an angle from the interval <-90°… 90°>. | ||||||
12.78.7.2 | Ai | Accelerometer - acceleration of the X-axis. Linear conversion A=0.002, B=-8 is required, the result is acceleration in g from the interval <-8 … 8>. | ||||||
12.78.9.2 | Ai | Accelerometer - acceleration of the Y-axis. Linear conversion A=0.002, B=-8 is required, the result is acceleration in g from the interval <-8 … 8>. | ||||||
12.78.11.2 | Ai | Accelerometer - acceleration of the Z-axis. Linear conversion A=0.002, B=-8 is required, the result is acceleration in g from the interval <-8 … 8>. | ||||||
12.78.13.2 | Ai | Accelerometer - X-axis calibration offset (deviation from the horizontal plane at the time of calibration). Linear conversion A=0.006, B=-180 is required, the result is an angle from the interval <-90°… 90°>. | ||||||
12.78.15.2 | Ai | Accelerometer - Y-axis calibration offset (deviation from the horizontal plane at the time of calibration). Linear conversion A=0.006, B=-180 is required, the result is an angle from the interval <-90°… 90°>. | ||||||
12.78.17.2 | Ai | Accelerometer - Z-axis calibration offset (deviation from the horizontal plane at the time of calibration). Linear conversion A=0.006, B=-180 is required, the result is an angle from the interval <-90°… 90°>. | ||||||
12.80.1.2 | Ai | Fuel quality - bioindex. Linear conversion A=0.03125, B=0 is required, the result is a bioindex in % of the interval <0 … 100>. | ||||||
12.80.3.2 | Ai | Fuel quality - viscosity. Linear conversion A=0.0003052, B=0 is required, the result is viscosity in mm2/s from the interval <0 … 20.00>. | ||||||
12.80.5.2 | Ai | Fuel quality - density. Linear conversion A=0.0003052, B=0 is required, the result is density in kg/dm3 from the interval <0 … 20.00>. | ||||||
12.80.7.2 | Ai | Fuel quality - relative permittivity. Linear conversion A=0.00012207031, B=0 is required, the result is relative permittivity from the interval <0 … 5.000>. | ||||||
12.80.9.2 | Ai |
| ||||||
12.80.11.4 | Ai | Fuel quality - volume at 15 ° C. Linear conversion A=0.001, B=0 is required, the result is the volume in liters adjusted to a temperature of 15 °C from the interval <0 … 10000.0>. |
Kotva | ||||
---|---|---|---|---|
|
...