Supported device types and versions 
Communication line configuration
Station configuration
I/O tag configuration
Document revisions

Kotva
typy_verzie
typy_verzie
Supported device types and versions

...

Dialog window station configuration - tab "Protocol parameters".
They influence some optional protocol parameters. The following station protocol parameters can be entered:

ParameterDescriptionUnitDefault Value
Kotva
port
port
Reader UDP Port
UDP port number for receiving messages from barcode readers.-3131
Kotva
timeout
timeout
Data Timeout
Timeout for receiving a message from barcode readers, scales or a watchdog.
If the Ping Active parameter is set to YES and the configured timeout elapses without receiving any message, the communication is considered to be interrupted and the station goes into communication error.
s120
Kotva
nr
nr
Nr. of Values for Output
The number of variables that the D2000 KOM sends in response to the message about weighted cones from the scales.-15
Kotva
ping
ping
Ping Active
Activation of MMP activity tracking - see the description of the Data Timeout parameter.YES/NOYES

Kotva
merany_bod
merany_bod
I/O tag configuration

...

Supported value types of I/O tags: Ai, Ci, Di, TxtI, Ao, Co, Dout, TxtO.
The address is specified as a decimal number or as a hexadecimal number with a hash at the beginning (e.g. #0A).

Value typeAddressDescription
I/O tag for handling barcode readers .
TxtI, Ci0Cone number from the message received from barcode readers (CONE_NR)
I/O tags for handling input from the scales.
Ai, Ci, Di, TxtI1 .. 10Individual components of the received message from the scales. According to the specification, there are five components (addresses 1-5):
  • ID - identifier of a message
  • CONE_NR - number of the cone
  • WEIGHT - weight of the cone mesaured by the multimeasurement workstation
  • WIDTH - width of the cone (diameter of the reel)
  • HEIGHT - height of the cone (width of the reel)
Should the message be extended, the D2000 supports defining up to 10 components without any modification of the protocol implementation.
Di0Trigger I/O tag for the message from the scales.
It is sets to True with the new timestamp when a new message from the scales arrived and the I/O tags from the previous row of the table have their values set.
I/O tags for handling the answer for the scales.
Co, TxtO, Ao1 .. 32Individual components of a response to the scales. According to the specification, there are sevent components (addresses 1-7):
  • ID - identifier of a message (must be equal to identifier of a message received from the scales).
  • MACHINE - number of a site where a cone was reeled
  • PRODUCT - name of a product
  • LENGTH - length of a fibre reeled on a cone
  • QUALITY - qualitative rating of the coil
  • DATE - date and time when reeling was completed
  • OPERATOR - name of the operator of the site where a cone was produced
Should the message be extended, the D2000 supports defining up to 32 components without any modification of the protocol implementation.
Note: component with address 2 cannot by of TxtO type, to avoid the collision with a trigger for the fibre rupture message.
Dout0Trigger I/O tag for the response to the scales. By writing to the trigger the application activates sending the response that contains the oputput I/O tags from the previous row of the table.
The number of values in the reply is determined by the configuration parameter Nr. Of Values for Output.
I/O tags for sending spontaneous messages about rupture of the fibre to the scales.
Co, TxtO, Ao1The first component of a spontaneous messages about rupture of the fibre sent to the scales.
Kotva
tr2
tr2
TxtO
2The second component and at the same time a trigger of a spontaneous messages about rupture of the fibre sent by D2000 KOM process to the scales.
The message contains components with addresses 1 and 2.

Kotva
revizie
revizie