IEC62056-21:2002 File I/O communication protocol
Supported device types and versions
Communication line configuration
Communication line protocol parameters
Communication station configuration
Station protocol parameters
I/O tag configuration
I/O address
Literature
Changes and modifications
Document revisions
Supported device types and versions
...
If directory is entered (in case of a platform Win32 with reverse solidus (\) at the end), all files that match the mask are processed (see station protocol parameters).
- Archive directory -path to the directory, where the processed files are archived. If directory is not set, the processed files will be cancelled.
...
Dialog window communication line configuration - tab Protocol parameters, select the protocol "IEC62056-21:2002 File I/O".
Table 1
Parameter | Description | Unit | Default value |
---|
| Analyzed profile. | - | P.01 |
Gorlitz PRM62 Module | Files from device Gorlitz PRM62 are analyzed. | YES/NO | NO |
Archive Subdirectory Time Mask | Mask for generation of subdirectories in main archive directory according to time of file processing or time stamp of file (the Input file is the entered directory). | - | rrrrmmdd |
Formatted Codes (Annex C) | Numerical addresses of I/O tags are used according to specification of standard IEC62056-21, Annex C. If numerical addresses are used, the station addresss is then acquired from the value of object with address D000, time stamp is acquired from the value of object with address C001. | YES/NO | NO |
External Command File 1, 2 | Complete path to periodically called external command file (.cmd). It is used only if non-empty value has been configured. It is possible to configure two independently executed command files with different periods. | - | - |
External Command File Period 1,2 | Call period of the external command file 1 or 2. | mi:ss | 1:00 |
Call External Command File 1,2 Synchronously | Call external command file 1 or 2 synchronously. | YES/NO | YES |
Ext. Command File After Activation | Complete path to the external command file wich is launched at change of redundancy status to HS. It is called only once and always synchronously. It is used only if non-empty value has been configured. | - | - |
| Show debug information about processed files. | YES/NO | YES |
| Show debug information with the content of processed files. | YES/NO | YES |
| Show debug information with measured values of the measure points. | YES/NO | YES |
| Period of input directory content check (if the input file is a directory). | mi:ss | 1:00 |
Unknown Files Backup Directory | File, where unknown files are saved (if the input file is directory). If it is not written, the files will be cancelled. The unknown files are the files inconvenient to mask (see station protocol parameters) or the station with required device number was not found. | - | - |
| Time data filter. If the time stamp of acquired values is different from current time more than stated number of hours in future, they are ignored. Enter 0 (zero) to ignore time filter. | hours | 24 |
| Time data filter. If the time stamp of acquired values is different from current time more than stated number of hours in past, they are ignored. Enter 0 (zero) to ignore time filter. | days | 31 |
Abnormal Timestamp Data Dir | Directory where the files with ignored data by time filter will be saved (Future Data Filter and History Data Filter). | - | - |
| Timeout, it is inserted after the file was analyzed. | ss.mss | 0.100 |
| Error file to write information about errors during processing (unknown file in directory, too old or too new values). Empty value means that this error file will not be created. | - | - |
Kotva |
---|
| komunikacna_stanica |
---|
| komunikacna_stanica |
---|
|
Communication station configuration
...
- Communication protocol "IEC62056-21:2002 File I/O".
- Station address - the station address is ignored if the input file is the particular file. If the directory is entered, the device number (electrometer) must be entered to assign the processed file to particular station. If the station with this number does not exist, the file is considered to be unknown (see communication line protocol parameter Unknown files backup directory).
Kotva |
---|
| stanica_parametre |
---|
| stanica_parametre |
---|
|
Station protocol parameters
...
Dialog window station configuration - tab Protocol parameters.
They influence some optional protocol parameters. The following station protocol parameters can be entered:
Table 2
Parameter | Description | Unit | Default value |
---|
| If the input file is a particular file, after this timeout passes without a file being processed, then the station value is transferred to communication error. | min | 45 |
| Mask for the name testing of the processed files. The following digit placeholder can be used: {N} - electrometer number, beware of number of figure, e.g.{NNNNNNNN}, {yy} or {yyyy} - year, {mm} - month, {dd} - day, {hh} - hour, {mi} - minute, {ss} - second. Exmple of mask: "Meter_{NNNNNNNN}{yy}{mm}{dd}{hh}{mi}.abl". Time stamp gained from the file name (if it is possible) is used at file saving to archive directory (see communication line protocol parameters Archive subdirectory time mask). If the electrometer number is gained, it is used for searching the proper station. In case of not using the mask, the parameter should be empty. The station addresss is then acquired from the value of object 0.0.0, C.1.0 or ZNR1 (ZNR1 in the past only in case ofGorlitz PRM62 Module, currently also for other types of energy meters). | - | - |
| Complete path to periodically called external command file (.cmd). The command file is called before accessing the input file. It is used only if non-empty value has been configured. | - | - |
External Command File Period | Call period of the external command file. | mi:ss | 1:00 |
Call Ext. Command File Synchronously | Call external command file synchronously. | YES/NO | YES |
| All values from communication (even old ones) go to the system as new values. | YES/NO | NO |
| The parameter is only used when analyzing files from the Gorlitz PRM62 (see the Gorlitz PRM62 Module line parameter). When enabled, attributes Invalid (invalid value), ShortPeriod (data for the whole measurement period are not available to electrometer), and TimeSet (time has been set during the measurement period) are mapped into flags FA, FB, FC . | YES/NO | NO |
| The date and time mask used to read historical profile data. The date and time mask used to read historical profile data. Meaning of the "z" flag - indication of monotonic time (0) or local time (1). |
| zyymmddhhmi |
I/O tag configuration
...