In the configuration of the system master repeater in the settings in the "Recording" section, it is necessary to configure "Recording Server IP Address" to the address of the computer with the D2000 KOM process and "Recording Server Port" to the UDP port number where the D2000 KOM process will listen. Subsequently, all repeaters will start sending copies of UDP packets with sound to the specified address and port.


Audio data received from the repeater is sorted and stored in individual files - one file for each call. At the start of a call, the D2000 KOM process publishes information to the input I/O tags (if they exist). After the end of the call, it will publish information about the closed recording to the I/O tag with the address FILE_READY, without waiting for confirmation from the ESL script, therefore it is advisable to implement handling with by a Server Event using the ON CHANGE action, or by a trigger event with a configured request queue, or with multiple execution enabled script (ENABLE action) so that values are handled even when there is a large number of changes.

The file (.dat) can then be converted to a standard audio file (.wav) using the conversion utility (dat2wav.exe) by Ipesoft. It can work with the hardware AMBE2+ codec (CT-24 module from ICOM) or with the software AMBE2+ codec (with lower sound quality).

Kotva
komunikacna_linka
komunikacna_linka
Communication line configuration

...