ALYA - lubrications communication protocol
Supported device types and versions
Communication line configuration
Communication station configuration
I/O tag configuration
Literature
Document revisions
Kotva | ||||
---|---|---|---|---|
|
...
This protocol supports data reading/writing from the controllers of ALYA lubricant reservoirs.
Since July 2015, this protocol supports a group of I/O tags for data reading / writing from Manex production lines - see Table 4.
Kotva | ||||
---|---|---|---|---|
|
...
Address | Meaning | Value type | Read/Write |
---|---|---|---|
AV | Current weight [kg] | Ai | R |
HI | Emergency minimum [kg] | Ai, Ao | R/W |
HA | Emergency maximum [kg] | Ai, Ao | R/W |
PN | Operating minimum [kg] | Ai, Ao | R/W |
PX | Operating maximum [kg] | Ai, Ao | R/W |
SP | Filling status (TRUE - filling, FALSE - draining) | Di | R |
EN | Error number - see Table 3 | Ai | R |
WS | Write to serial EEPROM (all changes of Ao must be written to EEPROM, if not, they vanish at the next reset) | Do | W |
RT | Reset (it retrieves the reset of control station) | Do | W |
...
Address | Meaning | Value type | Read/Write | ||||||
---|---|---|---|---|---|---|---|---|---|
RN | New weighted roving. After weighting and printing the weight ticket, the application writes a text string into I/O tag in the format: ID;CV;VZ;POC;ZD; where:
| TxtO | Write | ||||||
RX | Cancelling a roving. After an operator puts down the roving from the scale, the application will write the number of scale (1 or 2) into the I/O tag. | Co | Write | ||||||
| Number of spools on the lines. I/O tag is in the format "C1;C2;C3; … Cn;", where Ci represents an integral number that indicates number of spools on the line i. Example: "626;42;0;78;562;489;28;55;" | TxtI | Read | ||||||
NC | Reset the counters of spools on the lines. Write any valid value, to reset the counters. The control unit will send message in the format "C1;C2;C3; … Cn;", where Ci represents an integer number that indicates the number of spools which were included on the line i since the most recent information on the number of spools (see PC). This message will be a new value of I/O tag with the address NC. | TxtO | Write |
...