%HI_EDADebugCalcFunctionRec function


Function
Function initiates debugging of execution of EDAL formula defined when calling the function.
Declaration
INT %HI_EDACalcFunctionRec(
   INT in _refId,
   INT in _vectorType,
   TEXT in _vectorBodyEDAL,
   TIME in _bt,
   TIME in _et,
   RECORD () in _params
 [, UNIVAL in _param1, ..., _paramN]) 
 )

Parameters
_refId Reference to displayer of EDADebugger type (reference variable).
_vectorType Type of EDA vector. Only values that identify the calculated EDA vector are allowed (described in EDA System documentation – "EDA constants").
_vectorBodyEDAL Value of TEXT type that contains correct EDAL formula.
_bt Beginning of period for loading values.
_et End of period for loading values.
_params Structure of optional parameter of function.
_param1,..., _paramN Optional parameters for calculated vector.

Description
Function initiates debugging of execution of EDAL formula defined when calling the function. Debugging is done in EDADebugger environment. It is executed in the context of some existent connection (EDA Server – EDA Client), which is selected by previous calling the function %HI_EDADebugOpen. Function does not wait for termination of calculation which was initiated by this function.
Content of optional parameter structure -  version 1
  Parameter Data type Default Description
1 structVersion INT   Version of structure - 1.
2 cacheId INT 0 (default read cache) Identifier of cache. 
3 version INT/TEXT invalid (not defined) Identifier (id/code) of version from which the reading should be performed. 
4 envName TEXT "" Name of EDA environment that will be used for calculation. 
5 isIntegral BOOL @FALSE Flag of integrality of vector.
6 periodBeginTime TIME   Begin time of vector step (for general periodic vectors).
7 periodStepBase INT 0 Duration of basic step of periodic vector (for general periodic vectors).
8 periodStepCount INT 0 Number of basic steps in one vector period (for general periodic vectors).
9 periodTimeZone INT -1 Offset of time zone of vector in seconds <-12*3600 .. 12*3600>. It must be a multiple of 3600 or -1 (-1 - it uses time zone of process).

The return value is _ERR_NO_ERROR after the operation has ended successfully.