ALYA VT200 communication protocol
Supported device types and versions
Communication line configuration
Communication station configuration
I/O tag configuration
Literature
Changes and modifications
Document revisions
Supported device types and versions
This protocol enables to read the weighted values from the scale VT200 produced by ALYA Poprad. In addition to reading net weight and tare, it enables reading signs from keyboard, EAN-code and controlling the built-in monochromatic LCD display with a resolution 240x64 pixels.
Communication line configuration
- Category of communication line: TCP/IP-UDP
- Parameters of UDP line:
- Host: IP address of scale configured in the parameters of scale
- Port: UDP port of scale where requests are send. Default value (according to the documentation) is 3396.
Communication station configuration
- Communication protocol: ALYA VT200.
- Address of station is irrelevant and need not be defined. Only one station may be configured on one line.
Station protocol parameters
Key word | Full name | Meaning | Unit | Default value |
---|---|---|---|---|
LP | Local Port | UDP port where KOM awaits responses from the scale. Permitted values are in range 1-65535. | - | 3396 |
DT | Data Timeout | Timeout receiving message from scale on call from KOM process. | sec.mss | 0.500 |
ND | No Delete | Setting value to True will cause KOM process not to send buffer delete requests during reading of keystrokes and barcodes. Parameter is useful only during tuning of communication. | - | False |
I/O tag configuration
I/O tag address | I/O tag type | Meaning |
---|---|---|
NETTO | Ai | Net weight in kg. Note: If a scale reports the unsteady status (see I/O tag STEADY), I/O tag will be Invalid. |
TARA | Ai | Tare in kg. Note: If a scale reports the unsteady status (see I/O tag STEADY), I/O tag will be Invalid. |
STEADY | Di | Information whether a scale is steady (True) or not yet (False). |
ZERO | Di | Information whether a scale shows null weight (True) or not (False). |
RANGE | Ci | Scale range: 0, 1 or 2 according to the standard EN 45510 |
KEYCODE | TxtI | Keystroke(s) read from keyboard. Note: After reading keystroke(s) from a keyboard, they are deleted from a keyboard buffer so that during next reading from scale, this I/O tag is set to Invalid (unless parameter ND is set). Therefore, it is necessary to handle keystrokes within ESL script. |
BARCODE | TxtI | EAN-code read from a bar-code reader. Note: After reading bar-code from a bar-code reader, it is deleted from the reader so that during next reading from scale, this I/O tag is set to Invalid (unless parameter ND is set). Therefore, it is necessary to handle bar-codes within ESL script. |
DISPLAY | TxtO | I/O tag that is used for communication with monochromatic display on
scale. The string must consist of binary data in the format which is stated
in the manual from a producer. Message format is <XH><XL><YH><YL><WH><WL><HH><HL><data>, where:
|
Literature
-
Changes and modifications
-
Document revisions
- Ver. 1.0 – July 14, 2015 – created document